Outputs – Datalogic Scanning DS6400 User Manual

Page 38

Advertising
background image

DS6400

2

EXTERNAL DEVICE

DS6400

IN3A

Ground

V

+ 5V

~

~

+

-

EXTERNAL DEVICE

GND

V

IN4A

+ 5V

~

~

+

-

INREF

VS

Ground

Figure 28 - IN3/IN4 NPN Input Command using Scanner Power



Input devices can be supplied by either scanner power (VS and GND) or external power
supplies (Vext).

Electrical isolation between the input command logic and the scanner is maintained when
powering the input devices from an external supply voltage (Vext).

The driving logic of the input signals may be powered, for convenience, with the voltage
supply between pins 9 (VS) and 23 (GND) of the 26-pin I/O connector. In this case, however,
the device is no longer electrically isolated.

The voltage available on the 26-pin I/O connector, is physically the same as used to power
the scanner.


The electrical features of these inputs are:

Maximum voltage 30 V
Maximum current 10 mA


Outputs


Three general purpose outputs are available.

Pin Name

Function

8

OUT 1+

Configurable digital output 1 – positive pin

22

OUT 1-

Configurable digital output 1 – negative pin

11

OUT 2+

Configurable digital output 2 – positive pin

12

OUT 2-

Configurable digital output 2 – negative pin

16

OUT 3A

Configurable digital output 3 – polarity insensitive

17

OUT 3B

Configurable digital output 3 – polarity insensitive


The function of the three outputs OUT1, OUT2 and OUT3 can be defined by the user.
Refer to Genius™ Help On-Line for further details.

22