Datalogic Scanning DS6400 User Manual

Page 87

Advertising
background image

READING FEATURES

4

Minimum Code Height for ACR Reading (mm)

45°

30°

Conveyor

Speed

(m/s)

0.5 1 1.5

2 2.5

3 0.5

1 1.5 2 2.5

3

0.25

9 10 12 14 16 17

6 7 9 10 12 13

0.30

10 11 13 15 17 18

7 8 9 11 12 14

0.33

11 12 13 15 17 19

7 8 10 11 13 14

0.38

12 13 14 16 18 20

8 9 10 12 13 15

0.50

15 16 17 18 20 22

10 10 11 13 14 16

0.72

20 21 22 23 24 26

13 13 14 15 17 18

Code 39

Code Resolution

(mm)

1.00

27 28 29 30 31 32

17 17 18 19 20 21

Ratio 3:1; Interdigit = Module Size

Table 2

Minimum Code Height for ACR Reading (mm)

45°

30°

Conveyor

Speed

(m/s)

0.5 1 1.5

2 2.5

3 0.5

1 1.5 2 2.5

3

0.25

8 9 11 13 15 17

5 7 8 10 11 13

0.30

8 10 12 14 16 18

6 7 9 10 12 13

0.33

9 11 13 14 16 18

6 8 9 11 12 14

0.38

10 11 13 15 17 19

7 8 10 11 13 14

0.50

12 13 15 17 19 21

8 9 11 12 14 15

0.72

16 17 19 21 22 24

10 11 13 14 16 17

Code 128 – Ean 128

Code Resolution

(mm)

1.00

22 23 24 25 27 29

13 14 15 17 18 20

Table 3

Minimum Code Height for ACR Reading (mm)

45°

30°

Conveyor

Speed

(m/s)

0.5 1 1.5

2 2.5

3 0.5

1 1.5 2 2.5

3

0.25

8 9 11 13 15 17

5 7 8 10 11 13

0.30

9 10 12 14 16 18

6 7 9 10 12 13

0.33

9 11 13 14 16 18

6 8 9 11 12 14

0.38

10 11 13 15 17 19

7 8 10 11 13 14

0.50

13 14 15 17 19 21

8 9 11 12 14 15

0.72

17 18 19 21 22 24

11 12 13 14 16 17

Codabar

Code Resolution

(mm)

1.00

23 24 25 26 27 29

14 15 16 17 18 20

Ratio 3:1; Interdigit = Module Size

Table 4

Minimum Code Height for ACR Reading (mm)

45°

30°

Conveyor

Speed

(m/s)

0.5 1 1.5

2 2.5

3 0.5

1 1.5 2 2.5

3

0.25

7 9 10 12 14 16

5 6 8 9 11 12

0.30

8 9 11 13 15 17

6 7 8 10 11 13

0.33

9 10 11 13 15 17

6 7 9 10 12 13

0.38

10 11 12 14 16 18

7 7 9 10 12 13

0.50

12 13 14 15 17 19

8 9 10 11 13 14

0.72

16 17 18 19 20 22

10 11 12 13 14 16

EAN 8-13, UPC-A

Code Resolution

(mm)

1.00

22 23 24 24 25 26

13 14 15 16 16 18

Table 5

71

Advertising