Inputs – Datalogic Scanning DS6400 User Manual

Page 36

Advertising
background image

DS6400

2

Inputs


The inputs of the reader are on the 25-pin and 26-pin connector (Figure D, 1 and Figure E, 1)
of the DS6400.

These inputs are called EXT_TRIG/PS, IN2/ENC, IN3 and IN4.

Pin Name

Function

18

EXT_TRIG/PS A External trigger (polarity insensitive) for PS

19

EXT_TRIG/PS B External trigger (polarity insensitive) for PS

6

IN2/ENC A

Input signal 2 (polarity insensitive) for Encoder

10

IN2/ENC B

Input signal 2 (polarity insensitive) for Encoder

14

IN3A

Input signal 3 (polarity insensitive)

15

IN4A

Input signal 4 (polarity insensitive)

24

IN_REF

Common reference of IN3 and IN4 (polarity insensitive)


IN2/ENC is normally used for the Encoder input. In PackTrack™ mode, it detects the
conveyor speed. The maximum Encoder frequency is 2 KHz.

EXT_TRIG/PS is the main presence sensor. When active, this input tells the scanner to scan
for a code and that decoding can take place. The yellow LED (Figure C,3) indicates the
EXT_TRIG/PS is active.

IN3 and IN4 can be used as the stop signal for the reading phase.

All inputs are optocoupled, polarity insensitive, and driven by a constant current generator;
the command signal is filtered through an anti-disturbance circuit which generates a delay
which can be set to 5 ms or 500

µs. In particular, EXT_TRIG/PS, IN3 and IN4 share the

same value which usually corresponds to 5 ms when using a photoelectric sensor, while
IN2/ENC has a different value which is set to 500

µs when this input is used for the Encoder.


EXTERNAL TRIGGER/ENCODER

DS6400

+ 5V

A/B

Vext

B/A

V

~

~

+

-

Ground

Figure 23 – PNP Command Input Connection using External Power


EXTERNAL TRIGGER/ENCODER

DS6400

+ 5V

A/B

B/A

GND

V

~

~

+

-

VS

Ground

Figure 24 - PNP Command Input Connection using Scanner Power