Datalogic Scanning DS6400 User Manual

Page 60

Advertising
background image

DS6400

2

The following image shows a system consisting of six readers where:
• the system is powered by the PWR-240
• the master and all slaves are connected together through the CAB-610X cables
• the external signals (trigger, encoder, serial to host, etc.) are connected to the master

through the C-BOX 100

• one or more slaves are connected through CAB-63XX. The last slave must be terminated

with the BTK-6000


Slave 5

Slave 4

Slave 3

Slave 2

Slave1

BTK-6000

BTK-6000

CAB-610 CAB-610

PWR-240

CAB-63XX

CAB-60XX

Master

C-BOX 100**

PS*

***

Host

X

X

CAB-63XX

CAB-610X

CAB-610X

X

CAB-610

Encoder


*

P.S. (Presence Sensor) connected to External Trigger/PS input.

**

C-BOX 100 modified to accept scanner power

***

Encoder connected to IN2/ENC input.

Figure 58 – Small Synchronized Network with more than 2 Readers and Single Power Unit


NOTE

If a single power source is used, it is not necessary to separate groups of
scanners with "no power" cables (CAB-611X).

44

Advertising