INSTALLATION

2

How To Build A Simple Interface Test Cable:

The following wiring diagram shows a simple test cable including power, external
(push-button) trigger and PC RS232 COM port connections.

25-pin D-sub female

23

20

GND

RXAUX

TXAUX

21

DS6400

25

13

GND

VS

9-pin D-sub female

GND

TX

RX

PC

2

3

5

18

9

EXT TRIG A

VS

Power Supply

VS (15 – 30 VDC)
Power GND

Trigger

EXT TRIG B

19

Test Cable for DS6400


2.5 POSITIONING THE SCANNER


The DS6400 reader is able to decode moving barcode labels at a variety of angles, however
significant angular distortion may degrade reading performance.

When mounting DS6400 take into consideration these three ideal label position angles:
Pitch 0°, Skew 10° to 30° and Tilt 0°.

Follow the suggestions for the best orientation:

The Pitch angle is represented by the value P in Figure 45. Position the reader in order to
minimize the Pitch angle.

33

Figure 45 - "Pitch" Angle

P