Multidata network – Datalogic Scanning DS6400 User Manual

Page 62

Advertising
background image

DS6400

2

Multidata Network


In this layout, one master and up to 7 DS6400 slave readers have their own P.S. and
therefore multiple reading phases. Each P.S. is connected through a C-BOX 100, which in
turn is connected to its relative scanner through a CAB-60XX cable.

The master sends all the individual messages collected from the Lonworks interface as well
as its own to the Local Host through its C-BOX 100.

The following image shows a system consisting of five readers, which are all connected
together using CAB-611X cables and each scanner is individually powered by PG6000
through C-BOX 100.



Slave 1

Master

Slave 2

Slave 3

Slave 4

BTK-6000

CAB-611X

CAB-611X

CAB-611X

CAB-611X

No power

No power

No power

No power

C-BOX 100

C-BOX 100

C-BOX 100

C-BOX 100

C-BOX 100

Host

PG6000

PG6000

PG6000

PG6000

PG6000

BTK-6000

P.S.*

P.S.*

P.S.*

P.S.*

P.S.*


* P.S. (Presence Sensor) connected to External Trigger/PS input.

Figure 60 – Multidata Network