Cable & connector configurations, Introduction, General specifications – Datalogic Scanning Pegaso User Manual

Page 107: Wire requirements, Supply voltage, Docking connector, Appendix, Appendix e cable & connector configurations

Advertising
background image

Product Reference Guide

E-1

Appendix E

Cable & Connector Configurations

Introduction

The following pages contain information about standard interface cables for use in
interconnecting the Dock to power and/or peripheral devices.

General Specifications

Wire Requirements

Cable length should not exceed 15 feet.

Wire gauge:
5V and GND — 26 AWG min, 24 AWG recommended.
All others 28-26 AWG.

Supply Voltage

Current power supply voltage = 5V, 3 amp.

Docking Connector

Table E-1. Docking Connector Pin Definitions

PIN

Signal

Description

1

PWR GND

GND/Return

2

Cradle IN

When Grounded Mobile computer detects it is in the cradle

3

NC

No Connect

4

USB_N

USB D- Signal

5

USB_P

USB D+ Signal

6

GND

GND/Return

7

VBUS

USB VBUS Signal

8

USB ID

USB OTG ID Signal

9

TXD

RS232 TXD (Output from Mobile Computer)

10

RXD

RS232 RXD (Input to Mobile Computer)

11

RTS

RS232 RTS (Output from Mobile Computer)

Advertising