Programming Parameters

F-14

Pegaso™ Industrial PDA with Windows

®

CE

Table F-3. Other Controls

Code Parameter/ Description

I.D. #

Acceptable

Input

Defaults

Min

Max

Factory

Other Controls

Enter 1 for On and 0 for Off.

Enable Label
Programming

Enables/disables the ability to per-
form label programming.

FF00

On / Off

On

On

On

Beeper Volume

Adjusts the beeper volume.

FF20

00 = Off

00 - 09

(01 = Lowest;

07 = Highest;

08 = Higher;

09 = Lower)

07

07

07

Long Range
Trigger Mode

Selects the Long Range Trigger
mode.

0000

On = Release

Scan Off =

Spot Timeout

Off

Off

Off

Spotting Beam
Enable

Enables/disables the Spotting Beam

0001

On / Off

On

On

On

Spotting Beam
Timeout

Sets the duration of the spotting
beam before it automatically turns off.

0023

00 = 0.25 sec.

01 = 0.5 sec.
02 = 1.0 sec.
03 = 1.5 sec.
04 = 2.0 sec.

01

01

01

Release Scan
Timeout

Sets the duration of the scan before it
turns off.

0024

1-10

02

02

02

Number of
Good-Read
Beeps

Determines the number of beeps for
a good read indicator.

0020

01 - 04

01

01

01

Good-Read
Beep Tone

Adjusts the pitch of the beeper fre-
quency.

0021

00 - 07

(00 = Lowest;
07 = Highest)

00

00

00

Good-Read
Beep Duration

Determines the duration of a good
read beep.

0022

00 = 0.07 sec.
01 = 0.13 sec.
02 = 0.18 sec.
03 = 0.36 sec.

00

00

00

Send Symbol-
ogy Identifiers

Specifies the symbology identifier (if
any) that is sent by the decoder when
parameter Send Code ID (Index
0025) is set to 3. "ASCII" code zero
(null) used to indicate an identifier not
to be sent for the symbology.

0025

00 = Off

01 = DLM IDs*

02 = AIM IDs

03 = User IDs

00

01

00