Programming Parameters

F-10

Pegaso™ Industrial PDA with Windows

®

CE

If RSS-14, RSS-Expanded, RSS-Limited, or RSS-Composite symbologies are enabled for UCC-EAN
128, then that setting is also enabled for all other RSS symbologies.

NOTE: For the 2D Imager, RSS-Expanded User Code ID is used for RSS-14

RSS Limited

Enter 1 for On

and 0 for Off.

RSS Limited
Enable

Enables/disables the RSS Limited symbology.

0808

On / Off

Off

On

On

RSS Limited
to UCC-EAN
128

Instructs the decoder to transmit the label data
as one or more UCC-128 labels. The trans-
mission will use the UCC-128 AIM identifier.

080C

On / Off

Off

On

Off

If RSS-14, RSS-Expanded, RSS-Limited, or RSS-Composite symbologies are enabled for UCC-EAN
128, then that setting is also enabled for all other RSS symbologies.

NOTE: For the 2D Imager, RSS-Expanded User Code ID is used for RSS-Limited

RSS Expanded

Enter 1 for On

and 0 for Off.

RSS
Expanded
Enable

Enables/disables the RSS Expanded symbol-
ogy.

0810

On / Off

Off

On

On

RSS
Expanded to
UCC-EAN
128

Instructs the decoder to transmit the label data
as one or more UCC-128 labels. The trans-
mission will use the UCC-128 AIM identifier.

0804

On / Off

Off

On

Off

RSS
Expanded
Minimum

Set the minimum bar code label length to be
less than or equal to maximum label length.

0824

1 - 74

1

74

1

RSS
Expanded
Maximum

This feature specifies the maximum allowable
length of a label. The length includes check
and data characters, if applicable. Maximum
Label Length should be greater than or equal
to Minimum Label Length.

0825

1 - 74

1

74

74

RSS
Expanded
User Code ID

Specifies the symbology identifier (if any) that
is sent when parameter Send Code ID (Index
0025) is set to 3. "ASCII" code zero (null) is
used to indicate that an identifier is not to be
sent for the symbology.

0827

Any single

ASCII char-

acter (00 =

Off)

‘R’

‘R’

‘R’

Code Parameter/ Description

I.D. #

Acceptable

Input

Defaults

Min

Max

Factory