Bar code parameters, Codabar – Datalogic Scanning Pegaso User Manual

Page 111

Advertising
background image

Bar Code Parameters

Product Reference Guide

F-3

Bar Code Parameters

The following table lists the standard customer programmable settings for the Pegaso.

Table F-2. Programmable Standard Bar Code Settings

Code Parameter/ Description

I.D. #

Acceptable

Input

Defaults

Min

Max

Factory

Codabar

Enter 1 for On

and 0 for Off.

Enable

Enables/disables the Codabar symbology.

0300

On / Off

Off

On

On

Enable
Aggressive
Decoding

Enables more aggressive decoding algorithms
to be used in order to scan hard to read
labels.

0301

On / Off

Off

On

Off

Enable
Checksum

Requires the use of checksum characters to
verify a bar code.

0302

On / Off

Off

Off

Off

Send Check-
sum

Instructs the terminal to include the checksum
in the label transmission

0303

On / Off

Off

Off

Off

Send Start/
Stop

Instructs the decoder to transmit the decoded
start and stop characters of Codabar labels.
The start and stop characters will both be
translated as A, B, C, or D.

0305

On / Off

Off

On

Off

Convert to
CLSI

Restricts the Codabar decoder to only read
labels that conforms to "CLSI" specifications.
Label length must be 14, and the data is split
into fields of 1, 4, 5, and 4 characters sepa-
rated by spaces.

0306

On / Off

Off

Off

Off

Allow Wide
Intercharac-
ter Gaps

Allows wide gaps to appear between charac-
ters in a label.

0307

On / Off

Off

On

On

Minimum
Label Length

Set the minimum label length to be less than
or equal to maximum label length.

0320

01 - 50

01

01

04

Maximum
Label Length

This feature specifies the maximum allowable
length of a Codabar label. The length includes
check and data characters. Maximum Label
Length should be greater than or equal to Min-
imum Label Length.

0321

01 - 50

01

50

20

Read Verifi-
cation

Sets the number of times a label must be read
before it is transmitted.

0322

01 - 04

01

02

01

User ID

Specifies the symbology identifier (if any) that
is sent when parameter Send Code ID (Index
0025) is set to 3. "ASCII" code zero (null) is
used to indicate that an identifier is not to be
sent for the symbology.

0323

Any single

ASCII

character

(00 = Off)

'I'

'I'

'I'

Advertising