Programming Parameters

F-12

Pegaso™ Industrial PDA with Windows

®

CE

User ID

Specifies the symbology identifier (if any) that
is sent when parameter Send Code ID (Index
0025) is set to 3. "ASCII" code zero (null) is
used to indicate that an identifier is not to be
sent for the symbology

0125

Any single

ASCII

character

(00 = Off)

'X'

'X'

'X'

Universal Product Code-A (UPC-A)

Enter 1 for On

and 0 for Off.

Enable

Enables/disables the UPC-A symbology.

0500

On / Off

Off

On

On

Enable
Aggressive
Decoding

Enables more aggressive decoding algorithms
to be used in order to scan hard to read
labels.

0501

On / Off

Off

On

Off

Send Check
Digit

Includes check digit in the label which is trans-
mitted.

0502

On / Off

Off

On

Off

Send Sys-
tem Digit

Includes the system digit in the label transmis-
sion. For UPC-A, the system digit is always
zero.

0503

On / Off

Off

On

On

Convert UPC-
A to EAN-13

Instructs the decoder to expand UPC-A labels
to their EAN-13 equivalents. Any EAN-13
parameters will then apply to the result.

0504

On / Off

Off

On

Off

Read Verifi-
cation

Sets the number of times a label must be read
before it is transmitted.

0520

01 - 04

01

02

01

User ID

Specifies the symbology identifier (if any) sent
when parameter Send Code ID (Index 0025)
is set to 3. "ASCII" code zero (null) is used to
indicate that an identifier is not to be sent for
the symbology.

0521

Any single

ASCII

character

(00 = Off)

'A'

'A'

'A'

Universal Product Code-E (UPC-E)

Enter 1 for On

and 0 for Off.

Enable Sys-
tem Digit 0

Enables/disables UPC-E labels with a system
digit of zero.

0508

On / Off

Off

On

On

Enable
Aggressive
Decoding

Enables more aggressive decoding algorithms
to be used in order to scan hard to read
labels.

0509

On / Off

Off

On

Off

Send Check
Digit

Includes the check digit in the label which is
transmitted.

050A

On / Off

Off

On

Off

Send Sys-
tem Digit

This instructs the decoder to include the sys-
tem digit in the label transmission. For UPC-E,
the system digit is zero.

050B

On / Off

Off

On

Off

Code Parameter/ Description

I.D. #

Acceptable

Input

Defaults

Min

Max

Factory

Advertising