Rogramming – Skutt KilnMaster Kilns Manufactured after March 1 2006 User Manual

Page 20

Advertising
background image

20

p

rOgraMMing

the

r

aMp

/h

Old

M

Ode

p

rOgraMing

steps

s

tep

1

From Idle Mode, press

RAMP/HOLD.

Display will show PROG alternating with a number between 1 and 6.

s

tep

2

Input the

PROG Number of the Program you wish to create or run. (This is a number between 1 and

6 that you assign to a program which will be stored in permanent memory until it is replaced.) Press
ENTER
Display will show SEGS

s

tep

3

Input the total number of segments for your program.

Press ENTER.

Display will show RA 1

s

tep

4

Input the first heating rate in degrees per hour.

Press ENTER.

Display will show ˚F 1 (or ˚C 1 if using Celsius)

s

tep

5

Input the first temperature to reach.

Press ENTER.

Display will show HLD 1.

s

tep

6

Input the amount of

Hold Time in hours and minutes. Press ENTER.

Display will show ALRM if this the last segment you are entering, otherwise it will show RA 2.

s

tep

7

Repeat

steps 4 through 6 until all segments have been completed. The display will then flash ALRM

(Alarm) alternately with the current Alarm temperature. The default setting for no alarm is 9999. Enter

the desired alarm setting. Press ENTER
Display will briefly flash CPL

s

tep

8 – p

repare

v

enting

- (S

ee

deScription

on

p

age

15)

s

tep

9

The display will return to Idle mode. At this point the program is loaded and ready to start. Before

pressing START, it is a good idea to press REVIEW to make sure the program was input correctly. Be

sure to check that the lid latch is secure on kilns that are equipped with lid lifters. Press START and

the program will begin firing.
Display will briefly show ON and then will show the internal temperature of the kiln chamber unless

a DELAY START has been programmed in which case it will begin counting down minutes from the

designated Delay time.