pk speciFicatiOns

Model

PH

Volts

Amps

Watts

Copper

Wire

Size*

NEMA

Receptacle

Fuse or

Breaker Size

KM1227PK

1

240

60

14400

4

Direct Wire

80

KM1227PK

1

208

69

14352

4

Direct Wire

90

KM1227PK

3

240

40

14300

6

Direct Wire

50

KM1227PK

3

208

46.7

14300

6

Direct Wire

60

KM1231PK

1

240

72

17280

2

Direct Wire

90

KM1231PK

1

208

80

16640

2

Direct Wire

100

KM1231PK

3

240

44.5

17300

6

Direct Wire

60

KM1231PK

3

208

51.5

17300

6

Direct Wire

65

KM1627PK-LF

1

240

68

16320

4

Direct Wire

85

KM1627PK-LF

1

208

69

14352

4

Direct Wire

90

KM1627PK-LF

3

240

46

16300

6

Direct Wire

60

KM1627PK-LF

3

208

47

14300

6

Direct Wire

60

KM1627PK

3

240

66

23600

4

Direct Wire

85

KM1627PK

3

208

76

23600

4

Direct Wire

95

*For each additional 50 feet use heavier wire, numerically two numbers lower—for example, instead of #10, use #8. If

you anticipate installing any larger kiln in the future, use the heavier wire. Electrical specifications listed above are suggested guidelines.

Local electrical codes may vary.