Skutt KilnMaster Kilns Manufactured after March 1 2006 User Manual
Page 29
29
m
enu
f
eatuRes
alr4 (a
larM
4)
●
This is the factory default setting. If Output 4 is not being utilized this is the setting that should be
selected. This feature can also control an external alarm or autodialer to initiate if an Error Code
is generated or if the internal temperature of the kiln reaches the temperature programmed for the
ALARM setting of the program. To deactivate the alarm press ENTER
pct (p
ercent
O
n
)
●
Output 4 can be programmed to be on for a percent of the time output 2 is on. This option is used
when output 4 controls floor or lid elements. To ensure output 4 stays off at all times, use this option
and set the percentage to zero. The percent can be set from 0 to 150. There are currently no Skutt
Kiln designs that can utilize this feature.
Op a (O
ptiOn
a)
●
When option A is selected Output 4 will turn on when a CONE FIRE Mode program is started. When
the program has run and the kiln has cooled to 150˚F (65˚C), output 4 will turn off.
When a RAMP/HOLD program is inputted it will ask whether you want the fan (or other accessory) on
for each segment you program. After you Input the hold time for each segment the display will show
“FAN” along with the number of the segment you are programming. Alternately it will flash the current
setting, either “OFF” or “ON”. To change the setting toggle it with the 1 key and press ENTER to
select that setting.
OP b (
●
O
ptiOn
B)
During a CONE FIRE program Output 4 will turn on when START is pressed. It will then turn off
at 1450˚F (788˚C). It will turn back on when the kiln is cooling and the temperature drops below
1000˚F (538˚C). It will then turn off when the kiln cools to 150˚F (65˚C).
When a RAMP/HOLD program is inputted it will ask whether you want the fan (or other accessory)
on for each segment you program. After you Input the hold time for each segment the display will
show “FAN” along with the number of the segment you are programming. Alternately it will flash
the current setting, either “OFF” or “ON”. To change the setting toggle it with the 1 key and Press
ENTER to select that setting.
Op c (O
ptiOn
c)
●
When Option C is selected Output 4 does not come on during any portion of a CONE FIRE Mode
program.
When a RamP/hoLd program is inputted it will ask whether you want the fan (or other accessory)
on for each segment you program. After you Input the hold time for each segment the display will
show “FAN” along with the number of the segment you are programming. Alternately it will flash
the current setting, either “OFF” or “ON”. To change the setting toggle it with the “1” key and Press
ENTER to select that setting.
Max (M
axiMuM
p
rOgraMMaBle
t
eMperature
)
●
The Maximum Programmable Temperature setting is a great feature to use when other people may be
programming the kiln. It helps protect against an over fire by not allowing the programmer to input any
value over the designated limit. To set your firing limit access the “MAX” setting through the “CNFG”
menu, Input your desired limit and Press ENTER.