Ppendix, 714 wiring – Skutt KilnMaster Kilns Manufactured after March 1 2006 User Manual

Page 45

Advertising
background image

45

a

ppendix

5 —

e

leCtriCal

r

eQuireMents

Most important to proper operation of your new kiln is to make sure it has enough of the correct power to operate.

If this is done, your kiln will give

you years of satisfying service;

if not, your first firing could be

disappointing or even disastrous

for your kiln. The specification

charts on the following pages

show the recommended electrical

specifications for each kiln model.

If you are uncertain about your

existing outlets, have them checked

by an electrician. If you are

installing a new receptacle, have the

electrician follow this guide:

t

hree

-

phase

OperatiOn

On occasion we are asked if it is ok to use two legs of a 3 phase power supply to electrically connect a single

phase kiln. This is possible in most cases, however, you should have this connection made by a licensed electrician

who is familiar with 3 phase power supply and National and local electrical codes. It is not possible to connect a

3 phase kiln to 1 phase supply.

v

Oltage

As you can see from the chart, most Skutt models

are available in either 208 or 240 volt versions. The

exception is Model KM714 which is universal, and will

fire with a 240V or 208V power supply.

While 120/240V supply is still by far the most common

supply in residential communities, 120/208V supply is

increasingly encountered in commercial areas, schools

and occasionally newly-built communities.

If you find that the designated voltage of your kiln (found

on the serial plate) does not match your supply, do not

connect it. Doing so could damage the kiln and possibly

overheat wiring in your electrical supply. Contact the

factory for instructions on how to safely convert your

particular model.

714 Wiring

i

MpOrtant

:

The wall outlets for Model KM714 must be

powered by 3-wire 120/240-208V solid neutral supply. No. 10 wire is required for runs under 50 feet. 30 Amp

fuses or circuit breakers are recommended. The U-shaped fourth blade of the 4W30 Amp grounding plug is for the

solid green grounding wire. The blade opposite this U-shaped one takes the solid white neutral wire.