Skutt KilnMaster Kilns Manufactured after March 1 2006 User Manual
Page 35
35
Error
Codes
Descriptions
Causes
Correction
E- 8
When using the CONE FIRE MODE, the temperature is decreasing during the last ramp
segment. If this a KilnSitter Kiln using a Wall Mount Controller, KilnSitter may have shut
off the kiln.
Faulty relay
Broken Element
KilnSitter Shut-off kiln
Check relay.
Check Elements
Check Cone used in KilnSitter
pF
Continuous PF in display.
Indicates a long-term power outage The kiln has been shut
down.
Press 1 to clear the display and restart the
kiln.
Err p
A continuous Err P indicates a short term power outage has occured and the kiln has
continued with the program.
Power Outage
Power Surge
Press 1 to clear the display
If firing was in progress, it will continue.
Err-
The Err with a dash indicates there was a power loss to the controller while writing a
program to the non-volatile memory chip.
Power loss
Recheck the selected program, and
reprogram if necessary.
E- E
or
E- t
A hardware error has been detected by the controller software.
Hardware error
The controller must be returned for service.
E- d
The kiln or one of the zones in a zone control kiln, is more than 100
°
F (37
°
C) above the
travelling set point.
Stuck relay
Check relay
E- A
Invalid Program variable
Reprogram if problem persists have board
sent in for service
StUc
Key was held too long or was stuck
If problem persists after releasing key have
keypad replaced
E- bd
Controller is reading a board temperature above 160 degrees. Firing has stopped.
Room temperature is too hot..
Lower room temperature below 100
°
F
(37
°
C)
E- H
Analog to Digital Converter did not pass the self – check diagnostic test on reset.
Board will need to be serviced
FAIL
Steady display all thermocouples (T/C’s) have failed. If flashing thermocouples of a zone
control kiln has failed.
Change T/C
t