Skutt KilnMaster Kilns Manufactured after March 1 2006 User Manual

Page 35

Advertising
background image

35

Error

Codes

Descriptions

Causes

Correction

E- 8

When using the CONE FIRE MODE, the temperature is decreasing during the last ramp

segment. If this a KilnSitter Kiln using a Wall Mount Controller, KilnSitter may have shut

off the kiln.

Faulty relay

Broken Element

KilnSitter Shut-off kiln

Check relay.

Check Elements

Check Cone used in KilnSitter

pF

Continuous PF in display.

Indicates a long-term power outage The kiln has been shut

down.

Press 1 to clear the display and restart the

kiln.

Err p

A continuous Err P indicates a short term power outage has occured and the kiln has

continued with the program.

Power Outage

Power Surge

Press 1 to clear the display

If firing was in progress, it will continue.

Err-

The Err with a dash indicates there was a power loss to the controller while writing a

program to the non-volatile memory chip.

Power loss

Recheck the selected program, and

reprogram if necessary.

E- E

or

E- t

A hardware error has been detected by the controller software.

Hardware error

The controller must be returned for service.

E- d

The kiln or one of the zones in a zone control kiln, is more than 100

°

F (37

°

C) above the

travelling set point.

Stuck relay

Check relay

E- A

Invalid Program variable

Reprogram if problem persists have board

sent in for service

StUc

Key was held too long or was stuck

If problem persists after releasing key have

keypad replaced

E- bd

Controller is reading a board temperature above 160 degrees. Firing has stopped.

Room temperature is too hot..

Lower room temperature below 100

°

F

(37

°

C)

E- H

Analog to Digital Converter did not pass the self – check diagnostic test on reset.

Board will need to be serviced

FAIL

Steady display all thermocouples (T/C’s) have failed. If flashing thermocouples of a zone

control kiln has failed.

Change T/C

t

RoubLeshooting