Series 9205 Operations Manual Rev A

102

CO Factor

Displays the current CO Factor. When selected, this setting allows you to set the current CO Factor. The

range is 0 - 1000. NOTE: A CO Factor of 200 represents approximately 20.0% CO in the furnace.

H Factor

Displays the current H Factor. When selected, this setting allows you to set the current H Factor. The range

is 0 - 1000. NOTE: An H Factor of 400 represents approximately 40.0 % H

2

in the furnace.

Default Wait Limits

The 9205 controller uses default wait limits in

conjunction with recipe programs using the wait, wait

up, or wait down feature, or guaranteed soaks,

atmospheres, etc. The wait limits are in place to help

make sure a recipe will not continue to the next step

until the process variable is within the specified range.

The wait limits are both plus and minus the value of the

setpoint specified in the recipe.

Temp Wait Limit

This is the specific wait limit for the temperature PV. The range is: 0 to 4000.

Atm Wait Limit

This is the specific wait limit for the atmosphere PV.

Range is 0-40