Super Systems 9205 Series User Manual

Page 191

Advertising
background image

Series 9205 Operations Manual Rev A

190

Field

Factory Default Value

Temp Wait Limit

0

Atm Wait Limit

0.00

Furnace Name

Alarm 1 Setup

Setpoint

10

Alarm Type

PV1 NC/in band

Hysteresis

1

Smart Alarm

disabled

ON Delay Time (sec)

0

0 SP blocks alarm

no

BO/Impedance inhibits alarm

no

Inhibit source

none

Disable on open input

no

Alarm 2 Setup

Setpoint

15

Alarm Type

PV2 NC/in band

Hysteresis

1

Smart Alarm

disabled

ON Delay Time (sec)

0

0 SP blocks alarm

no

BO/Impedance inhibits alarm

no

Inhibit source

none

Disable on open input

no

Alarm 3 Setup

Setpoint

1400

Alarm Type

IN3 proc high

Hysteresis

1

Smart Alarm

disabled

ON Delay Time (sec)

0

0 SP blocks alarm

no

BO/Impedance inhibits alarm

no

Inhibit source

none

Disable on open input

yes

NOTE: The default setting for the process alarm is 1400°F. By default, this alarm is triggered by input 3

unless the 9205 is controlling % Carbon with a dual thermocouple setup, in which case the alarm is

triggered by input 2.

Relay Assignments

Relay 1

loop 2 fwd

Relay 2

loop 1 fwd

Relay 3

loop 1 rev

Relay 4

burn off

Relay 5

alarm 1

Relay 6

alarm 2

Relay 7

event 0