Super Systems 9205 Series User Manual

Page 184

Advertising
background image

xSeries 9205 Operations Manual Rev A

183

Appendix E – Factory Default Settings for the 9205 Controller

Field

Factory Default Value

Revision

Revision

2.61

Probe Setup

Burnoff Time (sec)

90

Burnoff Rec. Wait Time (sec)

120

Burnoff Interval (min)

720

Burnoff Minimum Millivolts

800

Burnoff Maximum Temperature

2000

Digital IN 4 Assignment

Event

Burnoff Minimum Millivolts Alarm SP

800

Burnoff Maximum Temperature Rise Limit

75

PID Loop 1 Setup

Prop Band (0 for On/Off)

20.0

Reset

0.10

Rate

0.00

Mode

Dual Reverse

Integral Preset

0

Cycle Time

16

Setpoint Change Limit

OFF

Low Limit

-100

High Limit

100

0 set point stops control

Yes

IN1 high limit shuts down ctrl

No

IN2 high limit shuts down ctrl

No

IN3 high limit shuts down ctrl

No

PID auto switch

No

Switch Point PID 1->2

99.99

Switch Point PID 2->3

99.99

Setpoint Lower Limit

-99.99

Setpoint Upper Limit

299.99

PV Source

internal

Minimum Fwd On Time (sec)

0.00

Minimum Fwd Off Time (sec)

0.00

Minimum Rev On Time (sec)

0.00

Minimum Rev Off Time (sec)

0.00

Positive Output Accumulator

5941.4

Negative Output Accumulator

0.0

Overshoot Control Logic

No

Ramp Detect Logic

No

Ramp Overshoot Control Level 1

No

Ramp Overshoot Control Level 2

No