Super Systems 9205 Series User Manual
Page 44

Series 9205 Operations Manual Rev A
43
Millivolts: Control is based off of what the millivolt reading is and also reads temperature.
Dew Point + Redundant TC: This functions the same way as the Dew Point option with an additional
thermocouple for Loop 3. The two thermocouples are used to control dew point, and the operator can
choose the setting that will be used.
Multiloop: Three loops of control can be assigned as selected.
Millivolts + Redundant TC: Control is based off of the millivolt reading and also reads temperature. Loop 3
is another thermocouple.
%Carbon + Dual Temp: This functions similarly to %Carbon. Input 2 is the control TC. IT is not used to
calculate carbon potential with input one and to control furnace temperature. Input 3 in the third loop and
is another TC.
IMPORTANT:
If the 9205 is controlling % Carbon or Dew Point, control will be disabled if either or both of
the following are true:
•
Millivolts registered by probe are below 500 mV or above 1300 mV.
•
Temperature registered by probe is below 900°F or above 2100°F.
Temperature Mode
This allows the operator to choose either degrees Fahrenheit or degrees Celsius for the temperature. The
options are °C or °F. Pressing OK will set the choice.
Loop 1 Instrument
Loop 1 (typical)
Instrument 5
Instrument 12
Instrument 19
Loop 2
Instrument 6
Instrument 13
Instrument 20
Loop 3
Instrument 7
Instrument 14
Instrument 21
Instrument 1
Instrument 8
Instrument 15
Instrument 22
Instrument 2
Instrument 9
Instrument 16
Instrument 23
Instrument 3
Instrument 10
Instrument 17
Instrument 24
Instrument 4
Instrument 11
Instrument 18
Instrument 25
Loop 2 Instrument
Loop 1
Instrument 5
Instrument 12
Instrument 19
Loop 2 (typical)
Instrument 6
Instrument 13
Instrument 20
Loop 3
Instrument 7
Instrument 14
Instrument 21
Instrument 1
Instrument 8
Instrument 15
Instrument 22
Instrument 2
Instrument 9
Instrument 16
Instrument 23
Instrument 3
Instrument 10
Instrument 17
Instrument 24
Instrument 4
Instrument 11
Instrument 18
Instrument 25
Event Instrument
Allows for a slave instrument (or internal) to be the defined event control device. The types of instruments
are: Internal, Instrument 1 – Instrument 25. Internal is typical.
Quench Instrument
Allows for slave instrument (or internal) to be the defined quench control device. This is setup in the
configurator furnace setup submenu. It will send the setpoint out to whatever instrument is configured for
quench. The types of instruments are: Loop 1 – Loop 3, Instrument 1 – Instrument 25.