The Rate will be the rate of degrees per minute to change the temperature until the setpoint is reached.

The range is 0.01 – 300.00.

REG_INQ

Value

Register

Option

This opcode will check a specific register against a specified value and can hold until the input matches the

value.

The Value is the value to check against. The range is -301 (disable) – 32767.

The Register is the specific register to check. The range is -1 (disable) – 32767.

The options are: Equal, > Or Equal (Greater than or equal to), or < Or Equal (Less than or equal to).

RESET

Recipe Number

Recipe Step

N/A

This opcode is used to clear all stacks and timers and start a program. The RESET is useful in a weekend

shut down program to restart the normal operating program.

The Recipe Number is the program number to start once everything has been reset. The range is 1 – 300.

The Recipe Step is the step number in the program to start at. The range is 1 – 24.

RUN_SLAVE

Recipe Number

Recipe Step

Slave Instrument

This opcode will start a recipe on the specified slave SSI recipe programmer instrument.

The Recipe Number is the program number to start on the slave instrument. The range is 1 – 300.

The Recipe Step is the program step to start on in the slave instrument. The range is 1 – 24.

The Slave Instrument is the slave instrument to select to start the recipe on (SSi recipe programmers only).

The options are: 1 – 25.

SET_AUX

Setpoint Value

N/A

Slave Instrument

This opcode sends a setpoint down to an auxiliary instrument.

The Setpoint Value is the setpoint to send down. The range is -301 (disable) – 30000.

The Slave Instrument is the slave instrument to send the setpoint down to (SSi recipe programmers only).

The options are: 1 – 25.