10

The HDX Routers Critical Hardware Alarms are as follows:

The

HDX

576 Router Critical Hardware Alarms:

1
2
3
4
5
6
7
8
9

10

POWER SUPPLY 1 (LEFT):
POWER SUPPLY 2 (RIGHT):
FANS:
TEMPERATURE WARNING:
TEMPERATURE SHUTDOWN:
CPU:
INPUT/OUTPUT CARDS:
ANY OF THE ABOVE
COMMON
GROUND

The

HDX

80 Router Critical Hardware Alarms:

Fan failure, temperature spikes, DC voltage and/or current out of range, AC power input interruption and module removed

Fan failure, temperature spikes, DC voltage and/or current out of range, AC power input interruption and module removed

Individual fan monitoring

Chassis over temperature, multiple sensors

Chassis over temperature causing shutdown

Card failure (Only with a redundant card)

SFP+ failure, laser output fault

1
2
3
4
5
6
7
8
9

10
11
12

POWER SUPPLY 1 (LEFT):
POWER SUPPLY 2:
POWER SUPPLY 3:
POWER SUPPLY 4 (RIGHT):
FANS:
TEMPERATURE WARNING:
TEMPERATURE SHUTDOWN:
CPU:
INPUT/OUTPUT CARDS:
ANY OF THE ABOVE
COMMON
GROUND

Fan failure, temperature spikes, DC voltage and/or current out of range, AC power input interruption or module removed

Fan failure, temperature spikes, DC voltage and/or current out of range, AC power input interruption or module removed

Individual fan monitoring

Chassis over temperature, multiple sensors

Chassis over temperature causing shutdown

Card failure (Only with a redundant card)

SFP+ failure, laser output fault

Fan failure, temperature spikes, DC voltage and/or current out of range, AC power input interruption or module removed

Fan failure, temperature spikes, DC voltage and/or current out of range, AC power input interruption or module removed

Figure 4: Alarm Descriptions and Drawing for the HDX80 and HDX576

Controller Card

The hot-swappable Controller Card connects the Router to an external Linux or Windows CPU.
The serial port can also be used for 3rd party controller integration (such as Crestron, AMX or
home-spun interfaces). Also, the

X4 Configurator Software (Appendix C) can be used to control the

Router via the LAN port.

If the HDX Router is to be controlled via ethernet, it will require a static IP address. This value
can be set via the DIP switch to the values listed below. The factory default setting will be
192.168.13.15.