W
o
rkpiece Gener
ation
117
Measuring tools
1. Insert the tool to be measured
2. Enter the tool number
Select ”Set T, S, F”
Enter the tool number
Press ”Save”
3. Measure the tool
Activate ”Measure tool”
Touch the diameter, then retract
Measure diameter and enter value as the ”Measuring
point coordinate X”
Touch the end face and enter ”0” for the ”Measuring point
coordinate Z”
4. Return to main menu
Press the Menu key
5. Repeat these steps for all tools
Setting the workpiece datum
1. Machine the end face
Use a measured tool
Enter machine data in ”Set T, S, F”
Use handwheels and jog controls to
machine the end face
2. Set workpiece datum
Select ”Setup”
Select ”Set axis values”
Touch end face with tool tip
Press ”Z=0” to accept position as
datum
3. Return to main menu
Press the Menu key