Center line as preset, 9 w or kpiece pr eset ting with a to uc h pr obe – HEIDENHAIN iTNC 530 (60642x-04) ISO programming User Manual
Page 525

HEIDENHAIN iTNC 530
525
14.9
W
or
kpiece
pr
eset
ting
with
a
to
uc
h
pr
obe
Center line as preset
Select the probe function: Press the PROBING soft
key
Position the touch probe at a position near the first
touch point
Select the probing direction by soft key
Start the probing procedure: Press the NC Start button
Position the touch probe at a position near the second
touch point
Start the probing procedure: Press the NC Start button
Datum:
Enter the coordinate of the preset in the menu
window, confirm with the SET DATUM soft key, or
write the value to a table (see "Writing the measured
values from touch probe cycles to datum tables",
page 510, or see "Writing the measured values from
touch probe cycles in the preset table", page 511, or
see "Storing measured values in the pallet preset
table", page 512)
To terminate the probe function, press the END key
X
Y
X+
X
X
Y
X
X+