Mounting

5.1

Requirements for Mounting

Requirements for the mounting location:

Danger to life due to fire or explosion
Despite careful construction, electrical devices can cause fires.

• Do not mount the inverter in areas containing highly flammable materials or gases.
• Do not mount the inverter in a potentially explosive atmosphere.

☐ Do not mount the inverter on a pillar.
☐ A solid support surface must be available for mounting, e.g. concrete or masonry.
☐ The support surface must be even. The difference between the outer anchoring points must not

exceed 5 mm.

☐ The mounting location must be suitable for the weight and dimensions of the inverter (see

Section 11 "Technical Data", page 52).

☐ The mounting location should not be exposed to direct solar irradiation. Direct solar irradiation

can cause the inverter to overheat. As a result, the inverter reduces its power output.

☐ The mounting location should be freely and safely accessible at all times without the need for

any auxiliary equipment (such as scaffolding or lifting platforms). Non-fulfillment of these
criteria may restrict servicing.

☐ To ensure optimum operation, the ambient temperature should be between -25°C and 40°C.
☐ Climatic conditions must be met (see Section 11 "Technical Data", page 52).