• Activate the WPS on your device.

☑ The connection with your device will be established automatically. Please note that

establishment of the connection to devices with Windows 7 or 8.1 can take up to 20
seconds.

2. If your smartphone, tablet PC or computer does not have a WPS function:

• Search for WLAN networks with your device.
• Select the inverter SSID SMA[serial number].
• Enter the inverter WLAN password. Within the first ten operating hours and prior to

closing the installation assistant for the first time, you can use the standard WLAN
password SMA12345. After this, you must use the device-specific inverter WLAN
password (WPA2-PSK), which is printed on the type label and the rear side of the Quick
Installation Guide included in delivery.

3. Enter 192.168.100.1 in the address line of the web browser and press the enter key.

☑ The login page of the user interface opens.

4. Log in as Installer or User. A new password must be assigned upon logging in for the first

time. To configure the inverter for the first time, login as an Installer.

5. Configure the inverter as desired.

Direct connection via Ethernet

Requirements:

☐ The inverter must be commissioned.
☐ A computer with an Ethernet interface must be available.
☐ One of the following web browsers must be installed: Firefox (as of version 32), Internet

Explorer (as of version 10), Safari (as of version 6) or Google Chrome (as of version 32).

☐ The inverter must be connected directly to a computer.
☐ The personal SMA Grid Guard code of the Installer must be available for the changing of

grid-relevant settings after completion of the first ten operating hours (see certificate
"Application for SMA Grid Guard Code" at www.SMA-Solar.com).

File export via Safari web browser not possible
When using the Safari web browser, the exporting of files (e.g. saving the current inverter
configuration or exporting events) is not possible for technical reasons.

• Use a different supported web browser.

Procedure:

1. Enter 169.254.100.1 in the address line of the web browser and press the enter key.

☑ The login page of the user interface opens.

2. Log in as Installer or User. A new password must be assigned upon logging in for the first

time. The initial configuration of the inverter may only be performed by a qualified person. In
this case, login as an Installer.

3. Configure the inverter as desired.