10 Appendix 2 Parameter Cross Reference

YASKAWA PL.A1000.01 G5 to A1000 - Product Transition Guide

39

Operation Mode
Selection

Reference Selection

b1-01

1

b1-01

1

b1-01

b1-01

0: Operator

0: Operator

1: Control circuit terminal
(analog input)

1: Control circuit terminal
(analog input)

2: Serial Communication

2: MEMOBUS comm.

3: Option PCB

3: Option PCB

4: EWS

4: Pulse train input

Operation Method
Selection

b1-02

1

b1-02

1

b1-02

b1-02

0: Operator

0: Operator

1: Control circuit terminal

1: Control circuit terminal

2: Serial Communication

2: MEMOBUS comm.

3: Option PCB

3: Option PCB

4: EWS

Not available

Stopping Method
Selection

b1-03

0

b1-03

0

b1-03

b1-03

0: Ramp to stop

0: Ramp to stop

1: Coast to stop

1: Coast to stop

2: DC Injection Braking

2: DC Injection Braking

3: Coast to stop with timer

3: Coast to stop with timer

Prohibition of Reverse
Operation

b1-04

0

b1-04

0

b1-04

b1-04

0: Reverse possible

0: Reverse possible

1: Reverse prohibited

1: Reverse prohibited

Operation Selection for
setting of E1-09 or
Less

b1-05

0

b1-05

0

b1-05

b1-05

0: Run at frequency reference

0: Run at frequency reference

1: Shut off drive output

1: Shut off drive output

2: Operate by E1-09

2: Operate by E1-09

3: Zero speed

3: Zero speed

Read sequence input
twice

b1-06

1

b1-06

1

b1-06

b1-06

0: 2 ms - 2 scans

0: 1 ms - 1 scan

1: 5 ms - 2 scans

1: 1 ms - 2 scans

Operation Selection
After Switching to
Remote Mode

b1-07

0

b1-07

0

b1-07

b1-07

0: Cycle Run command

0: Cycle Run command

1: Accept external Run cmd

1: Accept external Run cmd

Run Command
Selection in PRG
Mode

b1-08

0

b1-08

0

b1-08

b1-08

0: Disabled.

0: Disabled.

1: Run cmd always accepted

1: Run cmd always accepted

2: Cannot enter Program Mode

Run Command at
Power Up

b1-17

0

0: Prohibited
1: Allowed
Change b1-17 to 1.

DC Injection Braking

Zero speed level (DC
injection braking
starting frequency)

b2-01

0.5 Hz

b2-01

0.5 Hz

DC Injection Braking
current

b2-02

50 %

b2-02

50 %

DC Injection Braking
Time at Start

b2-03

0.00 s

b2-03

0.00 s

DC Injection Braking
Time at Stop

b2-04

0.00 s

b2-04

0.50 s*

*Determined by the control mode selected.

Magnetic Flux
Compensation volume

b2-08

0 %

b2-08

0 %

Speed Search

Speed Search Selection
at start

b3-01

0*

b3-01

0*

b3-01

b3-01

0: Disabled

0: Disabled

1: Enabled

1: Enabled

*Default value changes according to the control mode.

Speed Search
Operating Current

b3-02

100 %*

b3-02

120 %*

*Default value changes according to the control mode.

Speed Search

Speed Search
Deceleration Time

b3-03

2.0 s

b3-03

2.0 s

Timers

Timer Function On-
Delay Time

b4-01

0.0 s

b4-01

0.0 s

Timer Function Off-
Delay Time

b4-02

0.0 s

b4-02

0.0 s

Parameter Name

G5

A1000

Comments (Gray shading indicates default settings)

No.

Default

No.

Default

G5

A1000