10 Appendix 2 Parameter Cross Reference

YASKAWA PL.A1000.01 G5 to A1000 - Product Transition Guide

41

Zero Servo

Zero Servo Gain

b9-01

5

b9-01

5

Zero Servo Completion
Width

b9-02

10

b9-02

10

Accel/Decel Time

Acceleration Time 1

C1-01

10.0 s

C1-01

10.0 s

Deceleration Time 1

C1-02

10.0 s

C1-02

10.0 s

Acceleration Time 2

C1-03

10.0 s

C1-03

10.0 s

Deceleration Time 2

C1-04

10.0 s

C1-04

10.0 s

Acceleration Time 3

C1-05

10.0 s

C1-05

10.0 s

Deceleration Time 3

C1-06

10.0 s

C1-06

10.0 s

Acceleration Time 4

C1-07

10.0 s

C1-07

10.0 s

Deceleration Time 4

C1-08

10.0 s

C1-08

10.0 s

Emergency Stop Time

C1-09

10.0 s

C1-09

10.0 s

Accel/Decel Time
Setting Unit

C1-10

1

C1-10

1

C1-10

C1-10

0: 0.01 sec units

0: 0.01 sec units

1: 0.1 sec units

1: 0.1 sec units

Accel/Decel Time
Switch Frequency

C1-11

0.0 Hz

C1-11

0.0 Hz

S-Curve
Characteristics

S-Curve Characteristic
at Accel Start

C2-01

0.20 s

C2-01

0.20 s

S-Curve Characteristic
at Accel End

C2-02

0.20 s

C2-02

0.20 s

S-Curve Characteristic
at Decel Start

C2-03

0.20 s

C2-03

0.20 s

S-Curve Characteristic
at Decel End

C2-04

0.00 s

C2-04

0.00 s

Slip Compensation

Slip Compensation
Gain

C3-01

1.0*

C3-01

1.0*

*Determined by the control mode selected.

Slip Compensation
Primary Delay Time

C3-02

200 ms*

C3-02

200 ms*

*Determined by the control mode selected.

Slip Compensation
Limit

C3-03

200 %

C3-03

200 %

Slip Compensation
Selection during
Regeneration

C3-04

0

C3-04

0

C3-04

C3-04

0: Disabled

0: Disabled

1: Enabled

1: Enabled

Flux calculation
method

C3-05

0

-

0

This parameter is not available in A1000, and therefore does not
need to be set.

Output Voltage
Limited Operation
Selection

C3-06

0

C3-05

0

C3-06

C3-05

0: Disabled

0: Disabled

1: Enabled

1: Enabled

Torque Compensation

Torque Compensation
Gain

C4-01

1.00

C4-01

1.00

Torque Compensation
Primary Delay Time

C4-02

20 ms*

C4-02

20 ms*

*Determined by the control mode selected.

Torque Compensation
at Forward Start

C4-03

0.0 %

C4-03

0.0 %

Torque Compensation
at Reverse Start

C4-04

0.0 %

C4-04

0.0 %

Torque Compensation
Time Constant

C4-05

10 ms

C4-05

10 ms

Speed Control (ASR)

ASR Proportional Gain
1

C5-01

20.00*

C5-01

20.00*

*Determined by the control mode selected. Default shown here is
for when using Closed Loop Vector Control.

ASR Integral Time 1

C5-02

0.500 sec*

C5-02

0.500 sec*

ASR Proportional Gain
2

C5-03

20.00*

C5-03

20.00*

ASR Integral Time 2

C5-04

0.500 sec*

C5-04

0.500 s*

ASR Limit

C5-05

5.0 %

C5-05

5.0 %

ASR Primary Delay
Time Constant

C5-06

0.004 sec

C5-06

0.004 sec

* Default shown here is for when using Closed Loop Vector.

ASR Gain Switching
Frequency

C5-07

0.0 Hz

C5-07

0.0 Hz

ASR Integral Limit

C5-08

400 %

C5-08

400 %

Parameter Name

G5

A1000

Comments (Gray shading indicates default settings)

No.

Default

No.

Default

G5

A1000