10 Appendix 2 Parameter Cross Reference

YASKAWA PL.A1000.01 G5 to A1000 - Product Transition Guide

47

Digital Command Card

Digital Input Option

F3-01

0

F3-01

0

*The digital option card determines the setting

DI-08: 0 (8 bit)
DI-16H: Set switch S1 to determine input signal:
S1 switch 1: 2 (16 bit)
S1 switch S1: 1 (12 bit)

F3-01

F3-01

F3-03

0: BCD 1 % units

0: BCD 1 %
units

0: 8 bit

1: BCD 0.1 % units

1: BCD 0.1 %
units

1: 12 bit

2: BCD 0.01 % units

2: BCD
0.01 % units

2: 16 bit

Bit Selection for
Digital Card Input Data

F3-03

2*

3: BCD 1 Hz units

3: BCD 1 Hz
units

4: BCD 0.1 Hz units

4: BCD 0.1
Hz units

5: BCD 0.01 Hz units

5: BCD 0.01
Hz units

6: BCD, custom

6: BCD,
custom

7: Binary input

7: Binary
input

Analog Monitor Card

Channel 1 Monitor
Selection

F4-01

2

F4-01

102

F4-01, F4-03, H4-01, H4-04,

o1-01

F4-01, F4-03, H4-01, H4-04,

o1-01

01: Frequency reference

101: Frequency reference

02: Output frequency

102: Output frequency

03: Output current

103: Output current

05: Motor speed

105: Motor speed

06: Output voltage reference

106: Output voltage reference

07: Main circuit DC voltage

107: Main circuit DC voltage

08: Output power

108: Output power

09: Torque ref (Internal)

109: Torque ref (Internal)

15: Freq ref, 13 voltage

113: Freq ref, A1 voltage

16: Freq ref, 14 voltage

114: Freq ref, A2 voltage

17: Freq ref, 16 voltage

115: Freq ref, A3 voltage

18: Secondary current (Iq)

601: Secondary current (Iq)

19: Motor excitation current
(Id)

602: Motor excitation current
(Id)

20: Output after soft start

116: Output after soft start

21: ASR input

603: ASR input

22: ASR output

604: ASR output

23: Speed bias

Setting not available in A1000

24: PID feedback amount

501: PID feedback amount

26: Output voltage ref (Vq)

605: Output voltage ref (Vq)

27: Output voltage ref (Vd)

606: Output voltage ref (Vd))

32: ACR output (q-axis)

607: ACR output (q-axis)

33: ACR output (d-axis)

608: ACR output (d-axis)

36: PID input amount

502: PID input amount

37: PID output amount

503: PID output amount

38: PID setpoint

504: PID setpoint

Channel 1 Gain

F4-02

1.00

F4-02

100.0 %

Setting units differ between G5 and A1000. Set A1000 by
multiplying F4-02 in G5 by 100.

Channel 2 Monitor
Selection

F4-03

3*

F4-03

103*

*See the comments column for F4-01.

Channel 2 Gain

F4-04

50.0

F4-04

50.0 %

Set A1000 by multiplying F4-04 in G5 by 100.

Channel 1 output
Monitor Bias

F4-05

0.0 %

F4-05

0.0 %

Channel 2 Output
Monitor Bias

F4-06

0.0 %

F4-06

0.0 %

Parameter Name

G5

A1000

Comments (Gray shading indicates default settings)

No.

Default

No.

Default

G5

A1000