10 Appendix 2 Parameter Cross Reference

42

YASKAWA PL.A1000.01 G5 to A1000 - Product Transition Guide

Carrier Frequency

Carrier Frequency
Upper Limit

C6-01

10.0 kHz

C6-02

*

* Default setting is determined by the control mode and by drive
capacity. Change the setting for C6-02 to F.

C6-03

2.0 kHz

Carrier Frequency
Lower Limit

C6-02

10.0 kHz

C6-02

*

* Default setting is determined by the control mode and by drive
capacity. Change the setting for C6-02 = F.

C6-04

2.0 kHz

Carrier Frequency
Proportional Gain

C6-03

00

C6-05

0

Hunting Prevention
Function

Hunting prevention
function selection*

C7-01

1

N1-01

1

* These parameters are only displayed when using V/f Control of
with PG.

C7-01

n1-01

0: Disabled

0: Disabled

1: Enabled

1: Enabled

Hunting Prevention
Gain *

C7-02

1.00

n1-02

1.00

* These parameter are only displayed when using V/f Control of
V/f Control with PG.

Factory Tuning
Parameters

Carrier frequency
selection during
autotuning

C8-30

2

C6-09

0

C8-30

C6-09

0: 2 kHz

1: Setting value of C6-03*

1: Setting value of C6-01

1: Setting value of C6-03*

2: 5 kHz

0: 5 kHz

*Auto-Tuning set C6-09 tp va;ie pf C6-03.

Frequency Reference

Frequency Reference 1

d1-01

0.00 Hz

d1-01

0.00 Hz

Frequency Reference 2

d1-02

0.00 Hz

d1-02

0.00 Hz

Frequency Reference 3

d1-03

0.00 Hz

d1-03

0.00 Hz

Frequency Reference 4

d1-04

0.00 Hz

d1-04

0.00 Hz

Frequency Reference 5

d1-05

0.00 Hz

d1-05

0.00 Hz

Frequency Reference 6

d1-06

0.00 Hz

d1-06

0.00 Hz

Frequency Reference 7

d1-07

0.00 Hz

d1-07

0.00 Hz

Frequency Reference 8

d1-08

0.00 Hz

d1-08

0.00 Hz

Jog Frequency
Reference 9

d1-09

6.00 Hz

d1-09

0.00 Hz

Frequency Limits

Frequency Reference
Upper Limit Value

d2-01

100.0 %

d2-01

100.0 %

Frequency Reference
Lower Limit Value

d2-02

0.0 %

d2-02

0.0 %

Setting Prohibited
Frequency

Jump Frequency 1

d3-01

0.0 Hz

d3-01

0.0 Hz

Jump Frequency 2

d3-02

0.0 Hz

d3-02

0.0 Hz

Jump Frequency 3

d3-03

0.0 Hz

d3-03

0.0 Hz

Jump Frequency Width

d3-04

1.0 Hz

d3-04

1.0 Hz

Frequency Reference
Hold

Frequency Reference
Hold Function
Selection

d4-01

0

d4-01

0

d4-01

d4-01

0: Disabled

0: Disabled

1: Enabled

1: Enabled

+/- Speed limit

d4-02

10 %

d7-01

0.0 %

d4-02

d7-01

d7-02

d7-02

0.0 %

Set value

Set value

No need to set

No need to set

Negative

Torque Control

Torque Control
Selection

d5-01

0

d5-01

0

d5-01

d5-01

0: Speed Control

0: Speed Control

1: Torque Control

1: Torque Control

Frequency reference
hold function selection

d5-02

0 ms

d5-02

0 ms

Speed Limit Selection

d5-03

1

d5-03

1

d5-03

d5-03

1: Limited by b1-01

1: Limited by b1-01

2: Limited by d5-04

2: Limited by d5-04

Speed Limit

d5-04

0 %

d5-04

0 %

Speed Limit Bias

d5-05

10 %

d5-05

10 %

Speed/Torque Control
Switch Timer

d5-06

0 ms

d5-06

0 ms

Parameter Name

G5

A1000

Comments (Gray shading indicates default settings)

No.

Default

No.

Default

G5

A1000