Setting a user constant, Operation mode, Important – Yaskawa Varispeed-656 DC5 User Manual

Page 46

Advertising
background image

E-36

Setting a User Constant

The group level will be displayed when the DATA/ENTER Key is pressed at the program-
ming mode display.

Use the following procedure to set a constant.

The constant setting (drive mode is changed from Terminal to Operator with programming
mode) has been completed.

Operation Mode

Operation mode is the mode in which the VS-656DC5 can be operated.

Many user constants can't be changed when the VS-656DC5 is operating. Refer to A.1 Mon-
itor Constant List
for details.

The following monitor displays are possible in operation mode: The AC power supply fre-
quency, current or voltage, as well as fault information and the fault history.

When running the VS-656DC5 after using Digital Operator, press the MENU Key to enter the
operation mode and then press the DATA/ENTER Key from the operation mode display to bring up the
monitor display. Run commands cannot be received from any other display. (Monitor display in the
operation mode appears when the power is turned ON.)

Step

Key

Sequence

Digital Operator Display

Remarks

1

2

Press twice.

3

4

Changed to constant reading
(function) level.

5

6

7

8

9

Writes in the new setting.

After a few seconds, the Oper-
ator display is as shown on the
left.

10

EXAMPLE

MENU

DC5

∗ Main Menu ∗

Operation

DC5

∗ Main Menu ∗

Programming

Group b

Application

Sequence

Function b1

Entry Accepted

Function b1

sequence

Reference Source

Operator

Run Source

Terminals

b1-02 = 1

Terminals

b1-02 = 0

Operator

Run Source

Operator

DATA

ENTER

DATA

ENTER

DATA

ENTER

DATA

ENTER

DATA

ENTER

ESC

IMPORTANT

Advertising