Yaskawa V1000-Series Option SI-EM3D/V Dual Port EtherNet Modbus TCP/IP Technical Manual User Manual

Page 15

Advertising
background image

6.

For IP20/NEMA Type 1 enclosure models CIMR-VooAooooF, loosen the screw on the front of the NEMA Type

1 terminal cover and remove it from the drive. Refer to

Figure 8

for details.

Refer to

Figure 9

for drive models BA0006F to BA0018F, 2A0010F to 2A0069F, and 4A0001F to 4A0038F, which

require removing the plastic terminal cover prior to removing the NEMA Type 1 terminal cover.

Note:

Installing the option on an IP20/NEMA Type 1 enclosure drive voids NEMA Type 1 protection while maintaining IP20 conformity.

Figure 8 Remove the NEMA Type 1 Terminal Cover

(Models BA0001F to BA0003F and 2A0001F to 2A0006F)

Figure 9 Remove the Terminal Cover on an IP20/NEMA Type 1 Drive

(Models BA0006F to BA0018F; 2A0008F to 2A0069F; 4A0001F to 4A0038F)

7.

For models BA0001F to BA0003F and 2A0001F to 2A0006F, loosen the screws attaching the NEMA Type 1 conduit

bracket to the drive to remove the NEMA Type 1 conduit bracket.

Figure 10 Remove the NEMA Type 1 Conduit Bracket

(Models BA0001F to BA0003F and 2A0001F to 2A0006F)

8.

On models (BA0001F to BA0003F and 2A0001F to 2A0006F), the screw for the drive ground terminal also acts as

one of the screws that attaches the NEMA Type 1 conduit bracket to the drive. Reattach the NEMA Type 1 conduit

bracket according to Figure 27 and connect the drive-side of the ground wire to the drive ground terminal.

Note:

The different ground wires packaged with the option connect the option to different drive models. Select the proper ground wire

depending on drive size. Refer to

Table 5

on page

14

for ground wire selection by drive model.

5 Installation Procedure

YASKAWA SIEP YAICOM 17A V1000 Option Dual-Port Modbus TCP/IP SI-EM3D/V Technical Manual

15

Advertising
This manual is related to the following products: