Fault Condition

Fault Declared

Status Value

(U6-98/U6-99)

Description

Duplicate IP Address

BUS ERROR

1102

This node and at least one other node have the same IP

Address.

Default MAC Address

None

1103

Factory default MAC Address programmed into the

option. Return for reprogramming.

Network Link Down

BUS ERROR

1104

No network link to option.

Hardware Error

BUS ERROR

1105

Option card hardware has stopped functioning. Cycle

power to the drive.

Two drive monitor parameters, U6-98 and U6-99 assist the user in network troubleshooting.
• U6-98 displays the first declared fault since the last power cycle. U6-98 is only cleared upon drive power-up.
• U6-99 displays the present option status. U6-99 is cleared upon a network-issued fault reset and upon power-up.
If another fault occurs while the original fault is still active, parameter U6-98 retains the original fault value and U6-99 stores

the new fault status value.