Email Alerts Tab

The Email Alerts tab allows the user to configure four Email Fault/Alarm conditions. When the condition is true, one email

will be sent to the provided email address. Another email will not be sent until the condition becomes false and then true again.

A 30-second timer prevents emails from being sent when conditions reoccur immediately after being removed. The timer helps

limit the amount of emails sent regarding the same intermittent condition and helps to reduce network traffic by reducing

emails about reoccurring errors.

Figure 27 Email Alerts Tab View

n

Conditional Email Set-up

1.

Define the condition that will trigger the email by selecting a monitor parameter, a comparator, and a value. Set up

comparator values for the range of values to check in the chosen condition. If choosing only one condition and no OR

or AND are needed, set the “OR/AND” drop-down selection to “NotUsed”.

2.

Enter the email address where the alert will be sent.

3.

Enter the message that will appear in the email contents.

4.

Enter the email subject.

5.

Click the “Email Active” check box to enable the alert.

Clicking “Save to device” will save the entered information into the option memory.
Clicking “Cancel and reload” will cancel any pending edits and display the most recently saved settings from the option board.