Table 6.9 output signal—req, Table 6.10 output signal—serr, Output signal—req – Avago Technologies LSI53C876E User Manual
Page 237: Output signal—serr

DC Characteristics
6-5
Table 6.9
Output Signal—REQ/
Symbol
Parameter
Min
Max
Unit
Test Conditions
V
OH
Output high voltage
2.4
V
DD
V
−
16 mA
V
OL
Output low voltage
V
SS
0.4
V
16 mA
I
OZ
3-state leakage
−
10
10
µ
A
–
Note: REQ/ has a 25
µ
A pull-up that is enabled when TESTIN is low.
Table 6.10
Output Signal—SERR/
Symbol
Parameter
Min
Max
Unit
Test Conditions
V
OL
Output low voltage
V
SS
0.4
V
16 mA
I
OZ
3-state leakage
−
10
10
µ
A
–
Note: SERR/ has a 25
µ
A pull-up that is enabled when TESTIN is low.
Table 6.11
Bidirectional Signals—AD[31:0], C_BE/[3:0], FRAME/, IRDY/, TRDY/,
DEVSEL/, STOP/, PERR/, PAR
Symbol
Parameter
Min
Max
Unit
Test Conditions
V
IH
Input high voltage
2.0
V
DD
+0.5
V
–
V
IL
Input low voltage
V
SS
−
0.5
0.8
V
–
v
OH
Output high voltage
2.4
V
DD
V
16 mA
v
OL
Output low voltage
V
SS
0.4
V
16 mA
I
OZ
3-state leakage
−
10
10
µ
A
–
Note: All the signals in this table have 25
µ
A pull-ups that are enabled when TESTIN is low.