Read cycle, normal/fast memory, Read cycle, norma/fast memory, 128 kbytes), single byte – Avago Technologies LSI53C876E User Manual
Page 276: Access

6-44
Electrical Characteristics
Figure 6.21 Read Cycle, Normal/Fast Memory (
≥
128 Kbytes), Single Byte Access
Table 6.37
Read Cycle, Norma/Fast Memory (
≥
128 Kbytes), Single Byte Access
Symbol
Parameter
Min
Max
Unit
t
11
Address setup to MAS/ high
25
–
ns
t
12
Address hold from MAS/ high
15
–
ns
t
13
MAS/ pulse width
25
–
ns
t
14
MCE/ low to data clocked in
160
–
ns
t
15
Address valid to data clocked in
205
–
ns
t
16
MOE/ low to data clocked in
100
–
ns
t
17
Data hold from address, MOE/, MCE/ change
0
–
ns
t
18
Address out from MOE/, MCE/ high
50
–
ns
t
19
Data setup to CLK high
5
–
ns
CLK
t
19
t
12
MAD/
(Addr driven by
(Driven by LSI53C876)
MAS1/
(Driven by LSI53C876)
MAS0/
(Driven by LSI53C876)
MCE/
(Driven by LSI53C876)
MWE/
(Driven by LSI53C876)
MOE/
High Order
Address
Middle
Address
Order
Address
Low Order
Valid Read Data
t
11
t
13
t
15
t
14
t
16
t
18
t
17
LSI53C876- Data driven