User’s Manual of SGS-5220 Series

Allocation mode

In this mode the user allocates the amount of power that each port may reserve. The allocated/reserved power for each

port/PD is specified in the Maximum Power fields. The ports are shut down when total reserved powered exceeds the

amount of power that the power supply can deliver.

In this mode the port power is not turned on if the PD requests more available power.

LLDP mode

In this mode the ports of PoE power is managed and determined by LLDP Media protocol.

4.16.3 Power Over Ethernet Configuration

This section allows the user to inspect and configure the current PoE configuration settings

, screen in

Figure 4-16-2

appears.

Figure 4-16-2:

PoE Configuration Screenshot

The page includes the following fields:

Object

Description

Allows user enable or disable PoE function. It will causes all of PoE ports supply

or not supply power.

System PoE Admin

Mode

Allows user enable or disable PoE Temperature Protection.

PoE Temperature

Protection

There are Six modes for configuring how the ports/PDs may reserve power and

when to shut down ports.

PoE Management

Mode

Class-Consumption mode:

System offers PoE power according to PD real

313

Advertising