2 loop protection status – PLANET SGS-5220-24P2X User Manual

Page 325

Advertising
background image

User’s Manual of SGS-5220 Series

The interval between each loop protection PDU sent on each port. valid values

are 1 to 10 seconds.

Transmission Time

The period (in seconds) for which a port will be kept disabled in the event of a

loop is detected (and the port action shuts down the port). Valid values are 0 to

604800 seconds (7 days). A value of zero will keep a port disabled (until next

device restart).

Shutdown Time

Port Configuration

Object

Description

The switch port number of the port.

Port

Controls whether loop protection is enabled on this switch port.

Enable

Configures the action performed when a loop is detected on a port. Valid values

are Shutdown Port, Shutdown Port and Log or Log Only.

Action

Controls whether the port is actively generating loop protection PDU's, or

whether it is just passively looking for looped PDU's.

Tx Mode

Buttons

: Click to apply changes

:

Click to undo any changes made locally and revert to previously saved values.

4.17.2 Loop Protection Status

This Page displays the loop protection port status of the switch; screen in

Figure 4-17-2

appears.

Figure 4-17-2:

Loop Protection Status Screenshot

The Page includes the following fields:

Object

Description

Port

The Managed Switch port number of the logical port.