4.5 Serial Port Configuration

he screen in Figure 4-52 appears.

The page shows the converter’s serial Port configuration. T

Figure 4-52

Serial Port Configuration page screen

The page includes the following fields:

From the drop-down menu, select the serial port mode:

Mode

RS-232

RS-422

RS-485

Baudrate

serial device, such as a modem, must agree on a speed or

The unit and attached
baud rate to use for the serial connection, Valid baud rates.
It’s in the range of 300bps to 921600bps.

Character Bits

tted data package. The allowed value

is 5,6,7,8

Indicates the number of the bits in a transmi

The default is “8”.

Parity Type

y type. The default value is “none”.

Checks for the parit

Stop Bit

The stop bit follows the data and parity bits in serial communication. It indicates
the end of transmission. The default is “1”.

Hardware Flow Control

vices in a network to ensure it is

processed efficiently. Too much data arriving before a device is prepared to

Flow control manages data flow between de

manage it causes lost or retransmitted data. The default value is “none”.