A.2 device‘s rs-232/rs-422/rs-485 pin assignments, A.3 device‘s rj-45 pin assignments, Evice – PLANET ICS-102 User Manual

Page 70: Rs-232/rs-422/rs-485, Ssignments, Rj-45

Advertising
background image

User’s Manual of ICS-10x

-65-

1. This utility show all necessary information from the devices, such as MAC Address, Device Name, firmware version,

Device IP Subnet address, also can assign new password, IP Subnet address and description for the devices.

2. After setup completed, press “Update Device”, “Update Multi” or “Update All” button to take affect. The meaning of

the 3 buttons above are shown as below:

Update Device

: use current setting on one single device.

Update Multi:

use current setting on choose multi-devices.

Update All:

use current setting on whole devices in the list.

The same functions mentioned above also can be finding in “Option” tools bar.

3. To click the “Control Packet Force Broadcast” function, it can allow assign new setting value to the Web Smart

Switch under different IP subnet address.

6. Press “Connect to Device” button then the Web login screen appears.

7. Press “Exit” button to shutdown the planet Smart Discovery Utility.

A.2 Device‘s RS-232/RS-422/RS-485 Pin Assignments

DB9 Pin Define for RS-232 / RS-422 / RS-485

DB9-PIN

RS-232

RS-422/485

4-wire

RS-485

2-wire

1 DCD

2 RXD

3 TXD

4 DTR

RX-

Data

B(-)

5 GND

6 DSR

TX-

7 RTS

RX+

Data

A(+)

8 CTS

TX+

9 RI

A.3 Device‘s RJ-45 Pin Assignments

10/100Mbps, 10/100Base-TX

Contact

MDI

MDI-X

1 1

(TX

+) 3

2 2

(TX

-) 6

3 3

(RX

+) 1

6

6 (RX -)

2

4, 5, 7, 8

Not used

Not used

Implicit implementation of the crossover function within a twisted-pair cable, or at a wiring panel, while not expressly
forbidden, is beyond the scope of this standard.