ProSoft Technology PS69-DPS User Manual

Page 20

Advertising
background image

Start Here

PS69-DPS ♦ CompactLogix or MicroLogix Platform

User Manual

Profibus DP Slave Communication Module

Page 20 of 108

ProSoft Technology, Inc.

May 9, 2014

Now the PS69-DPS module will be visible at the I/O Configuration section

1.8.3 Import the Ladder Rung

1 Open your application in RSLogix 5000.
2 To create a new routine, expand the T

ASKS

folder, and then expand the M

AIN

T

ASK

folder.

3 On the M

AIN

P

ROGRAM

folder, click the right mouse button to open a shortcut

menu. On the shortcut menu, choose N

EW

R

OUTINE

.

4 In the N

EW

R

OUTINE

dialog box, enter the name and description of your

routine, and then click OK.

In this example we are demonstrating the

importing of the ladder rung using the default MainRoutine. In the case where
you create a routine by an other name for placing the Add-On instruction,
then in your original routine where your other ladder logic is located you need
to add a rung with a jump instruction to the new routine holding the Add-On
instruction.

5 Select an empty rung in the new routine, and then click the right mouse

button to open a shortcut menu. On the shortcut menu, choose "I

MPORT

R

UNG

".

Advertising