DPS_DPV1C1_RW_RESP_CONFIRM

Parameter

Data Type

Value

Meaning

Reserved1

INT

0

Reserved

Reserved2

INT

0

Reserved

Answer

SINT

17

Command for DPV1 Class 1 Read Response

Failure

SINT

0

no error

Reserved4

INT

0

Reserved

RwResp

SINT

2

2 = Write Resp Request. Reply from resp. request

MaAdr

SINT

0.. 125

Bus Address of Master which sent the request. Reply from
resp. request

Slot

INT

0.. 254

Slot Number. Reply from resp. request

Index

SINT

0.. 254

Index. Reply from resp. request

DataLen

SINT

1.. 240
(x)

Length of the data block to be written.

ErrCode1

SINT

E1

DPV1 Error code 1 Reply from resp. request

ErrCode2

SINT

E2

DPV1 Error code 2 Reply from resp. request

Data[1..x]

SINT[1..240]

0-255

DPV1 Write data the Master has sent.

CIP MSG Parameterization

Parameter

Value

Remarks

Message Type

CIP Generic

Service Type

Custom

Service Code

64 hex

Service Code "Bridge Message"

Class

65 hex

CIP Object "CIP_MSG_BRIDGE""

Instance

1

Attribute

0

Source Element

Dpv1RWRespReq

Reference to a Tag of type
DPS_DPV1C1_RW_RESP_REQUEST

Destination

Dpv1RWRespCnf

Reference to a Tag of type
DPS_DPV1C1_RW_RESP_CONFIRM

Source Length

16

Corresponds to the constant size of DPS_DPV1C1_RW
_REQUEST structure

DPV1 Class 1 Alarm Request
The DPV1 Class 1 Alarm Request is used to indicate a DPV1 Alarm to the
connected Master. The MSG instruction Request/Confirmation format is as
follows.