DPS_DPV1C1_ALARM_REQUEST

Parameter

Data Type

Value

Description

Reserved1

INT

0

Reserved

Reserved2

INT

0

Reserved

Reserved3

INT

0

Reserved

Command

SINT

18

Command for Service
DPV1 Class 1 Alarm Request

Reserved4

SINT

0

Reserved

Reserved5

INT

0

Reserved

SlotNumber

INT

0...254

Alarm Slot Number

SequenceNumber

SINT

0...31

Alarm Sequence Number

DataCnt

SINT

0...28
(x)

Number of User Specific Alarm Data

AlarmType

SINT

1-6,
32-126

Alarm Type:Diag,-Process,-Pull,-Plug,-Status,-Update,
Manufacturer specific

Specifier

SINT

0...7

Alarm Specifier
Bit 0...1: Alarm Specifier
Bit 2: Add Ack bit

Data[0..x]

SINT[28]

0…255

User Specific Alarm Data.

DPS_B_ACYC_C1_ALARM _CONFIRM

Parameter

Data Type

Value

Meaning

Reserved1

INT

0

Reserved

Reserved2

INT

0

Reserved

Answer

SINT

18

Answer DPS_B_ACYC_C1_ALARM

Failure

SINT

e

Error, status (see following section)

Reserved3

INT

0

Reserved

Reserved4

INT

0

Reserved

SlotNumber

INT

0...254

Alarm Slot Number, Reply from request

SequenceNumber

SINT

0...31

Alarm Sequence Number, Reply from request

DataCnt

SINT

0

not used

DataType

SINT

1-6,
32-126

Alarm Type, Reply from request

Specifier

SINT

0..7

Alarm Specifier, Reply from request