Diagnostics and Troubleshooting

MVI46-MBP ♦ SLC Platform

Modbus Plus Communication Module

ProSoft Technology, Inc.

Page 25 of 101

February 19, 2008

Viewing Module Configuration

Press [C] to view the Module Configuration screen.

Use this command to display the current configuration and statistics for the
module.

Opening the Database Menu

Press [D] to open the Database View menu. Use this menu command to view the
current contents of the module's database.

Opening the Command Error List Menu

Press [I] to open the Command Error List. This list consists of multiple pages of
command list error/status data. Press [?] to view a list of commands available on
this menu.

Viewing Global Input Status and Counter Data

Press [G] to view the Global Input Status and Counter data for each Modbus
Plus node defined in the Device Definition Table.

The Status data area displays the current status of each node on the network.
Refer to the Module Set Up section for a complete listing and definition of the
status codes. The Counters section displays the number of Global Input data
messages received from the device.

Opening the Device Definition List Menu

Press [L] to open the Device Definition List. This list consists of multiple pages of
device definition data. Press [?] to view a list of commands available on this
menu.