101

Handling of Numerical Value

3

SEQUENCE PRO

G

RAM

M

ING

3.21 Handling of Numerical Value

The built-in PLC function has instructions that handle numerical values indicated in 16
bits.
The most significant bit of the 16 bits is used to judge whether the value is positive or
negative. Therefore, the numerical values that can be handled as 16 bits are as
follows.

16 bits: -32768 to 32767

The decimal notation and hexadecimal notation correspond as indicated below.

POINT

•Numerical value setting method

1) Decimal number

2) Hexadecimal number

Decimal Notation

Hexadecimal Notation

32767

H7FFF

to

to

5

H0005

4

H0004

3

H0003

2

H0002

1

H0001

0

H0000

-1

HFFFF

-2

HFFFE

-3

HFFFD

-4

HFFFC

-5

HFFFB

to

to

-32768

H8000

10 is stored into D10 in BIN.

-10 is stored into D10 in BIN.

10 is stored into D10 in
hexadecimal.