59

Buffer Memory

2

CC-

L

in

k CO

M

M

UNICAT

ION

2.4.3

Remote registers Pr.544=100

(Master module to inverter(FR-A7NC))

• Data to be sent to the remote registers (RWW) of the remote device station are

stored.

• Four words are used for each station.

Correspondences between Master Station Buffer Memory Addresses and Station
Numbers

Station

No.

Buffer

Memory

Address

Station

No.

Buffer

Memory

Address

Station

No.

Buffer

Memory

Address

Station

No.

Buffer

Memory

Address

1

1E0

H

to 1E3

H

17

220

H

to 223

H

33

260

H

to 263

H

49

2A0

H

to 2A3

H

2

1E4

H

to 1E7

H

18

224

H

to 227

H

34

264

H

to 267

H

50

2A4

H

to 2A7

H

3

1E8

H

to 1EB

H

19

228

H

to 22B

H

35

268

H

to 26B

H

51

2A8

H

to 2AB

H

4

1EC

H

to 1EF

H

20

22C

H

to 22F

H

36

26C

H

to 26F

H

52

2AC

H

to 2AF

H

5

1F0

H

to 1F3

H

21

230

H

to 233

H

37

270

H

to 273

H

53

2B0

H

to 2B3

H

6

1F4

H

to 1F7

H

22

234

H

to 237

H

38

274

H

to 277

H

54

2B4

H

to 2B7

H

7

1F8

H

to 1FB

H

23

238

H

to 23B

H

39

278

H

to 27B

H

55

2B8

H

to 2BB

H

8

1FC

H

to 1FF

H

24

23C

H

to 23F

H

40

27C

H

to 27F

H

56

2BC

H

to 2BF

H

9

200

H

to 203

H

25

240

H

to 243

H

41

280

H

to 283

H

57

2C0

H

to 2C3

H

10

204

H

to 207

H

26

244

H

to 247

H

42

284

H

to 287

H

58

2C4

H

to 2C7

H

11

208

H

to 20B

H

27

248

H

to 24B

H

43

288

H

to 28B

H

59

2C8

H

to 2CB

H

12

20C

H

to 20F

H

28

24C

H

to 24F

H

44

28C

H

to 28F

H

60

2CC

H

to 2CF

H

13

210

H

to 213

H

29

250

H

to 253

H

45

290

H

to 293

H

61

2D0

H

to 2D3

H

14

214

H

to 217

H

30

254

H

to 257

H

46

294

H

to 297

H

62

2D4

H

to 2D7

H

15

218

H

to 21B

H

31

258

H

to 25B

H

47

298

H

to 29B

H

63

2D8

H

to 2DB

H

16

21C

H

to 21F

H

32

25C

H

to 25F

H

48

29C

H

to 29F

H

64

2DC

H

to 2DF

H

FR-A700 series

Remote registers (RWw)

1E0

H

1E1

H

1E2

H

1E3

H

1E4

H

1E5

H

1E6

H

1E7

H

1E8

H

1E9

H

1EA

H

1EB

H

1EC

H

1ED

H

1EE

H

1EF

H

Addresses

Master station

Remote device station

(Station No. 1: 1 station occupied)

RW

W

0

RW

W

1

RW

W

2

RW

W

3

RW

W

4

RW

W

5

RW

W

6

RW

W

7

RW

W

8

RW

W

9

RW

W

A

RW

W

B

RW

W

C

RW

W

D

RW

W

E

RW

W

F

RW

W

FD

RW

W

FC

RW

W

FE

RW

W

FF

1F0

H

2DB

H

2DC

H

2DD

H

2DE

H

2DF

H

to

RW

W

0

RW

W

1

RW

W

2

RW

W

3

Inverter

D9063
D9064
D9065

D9062

For station
No.1

For station
No.2

For station
No.3

For station
No.4

For station
No.64

to

Advertising