21

Inverter Status Monitoring, Special Registers

for Control

1

P

L

C

FU

N

C

TI

O

N

(2) Error history (error codes and error definitions)

The inverter stores the error codes of the errors that occurred.
The error codes of up to eight errors are stored in the order as shown below and are
always read-enabled (write-disabled).

<Error code storing method details>

Refer to the Inverter instruction manual (applied) for alarm definition details.

b15 to b8

b7 to b0

D9136 Error history 2 Error history 1
D9137 Error history 4 Error history 3
D9138 Error history 6 Error history 5
D9139 Error history 8 Error history 7

Older

Newer

Data

Description

H00

No alarm

H10

E.OC1

H11

E.OC2

H12

E.OC3

H20

E.OV1

H21

E.OV2

H22

E.OV3

H30

E.THT

H31

E.THM

H40

E.FIN

H50

E.IPF

H51

E.UVT

H52

E.ILF

H60

E.OLT

H70

E.BE

H80

E.GF

H81

E.LF

H90

E.OHT

H91

E.PTC

HA0

E.OPT

HA3

E.OP3

HB0

E.PE

HB1

E.PUE

HB2

E.RET

HB3

E.PE2

HC0

E.CPU

HC1

E.CTE

HC2

E.P24

HC4

E.CDO

HC5

E.IOH

HC6

E.SER

HC7

E.AIE

HC8

E.USB

HD0

E.OS

HD1

E.OSD

Data

Description

HD2

E.ECT

HD3

E.OD

HD5

E.MB1

HD6

E.MB2

HD7

E.MB3

HD8

E.MB4

HD9

E.MB5

HDA

E.MB6

HDB

E.MB7

HDC

E.EP

HF1

E.1

HF2

E.2

HF3

E.3

HF6

E.6

HF7

E.7

HFB

E.11

HFD

E.13

Data

Description