3.25.5 Output Instructions : Bit device, timer, counter ... OUT

Functions

(1) Outputs the operation result up to OUT instruction to the specified device.

Usable Devices

Digit

Designation

Error

Flag

Bit devices

Word (16-bit)

devices

Constants Level

X

Y

M

T

C

D

K

H

N

(M9010,

M9011)

Bit device

{

{

Timer

Device

{

Setting

{

{

Counter

Device

{

Setting

{

{

OUT (Y, M)

Operation Result

OUT Instruction

Coil

Contacts

N/O contact

N/C contact

OFF

OFF

Not energize

Energize

ON

ON

Energize

Not energize

REMARKS

Three steps are used for the OUT instruction only when the following device is used.

Special relay (M)

T0

T0

C0

C1

OUT

Y15

Device number

K50

Device number (T0 to 7)

D10

K50

Device number (C0 to 7)

OUT

OUT

Device number (T0 to 7)

Device number (C0 to 7)

(Y, M)

(T)

(C)

D10

Setting Any of data register

contents 1 to 32767
is valid

Setting Any of 1 to 32767 is

valid

Setting Any of 1 to 32767 is

valid

Setting Any of data register

contents 1 to 32767
is valid