34

Inverter Parameter Read/Write Method

1.8 Inverter Parameter Read/Write Method

1.8.1

Reading the inverter parameters

When reading the parameter, the parameter description is stored to D9242(D9244) by
storing the parameter number to D9241(D9243) and turning Y28 (Y2A) on. When
reading is completed, X28 (X2A) turns ON to notify the completion. (The device
number within parentheses is used to read the parameter setting value from
EEPROM.)
When reading the calibration parameter (Pr. 902 to Pr. 939), set the following value to
D9234 (D9235) to read each calibration parameter value.
0: Setting value (Frequency/Toruque)

1: Parameter-set analog value

2: Analog value input from terminal

When access error occurs such as "parameter does not exist", value obtained by adding the

parameter number and 8000H is stored to D9150. (Refer to page 33)

Device No.

Name

Command Completion

Data Access Enable

Condition

(Operation mode)

D9241

Parameter number (RAM)

Y28

X28

Always

D9242

Parameter description (RAM)

D9234

Second parameter changing
(RAM)

D9243

Parameter number (EEPROM)

Y2A

X2A

PU, NET operation mode

(as in Pr.77)

D9244

Parameter description

(EEPROM)

D9235

Second parameter changing
(EEPROM