3.13 Function List

Function

Description

Remote RUN/STOP

This function performs remote RUN/STOP from outside the
inverter when SQ-SD are shorted (PLC function in RUN
status (P.RUN lit)).

Watchdog timer variable
(10 to 2000ms)

The watchdog timer is an internal timer of the sequence
function designed to detect hardware or program faults and
can be changed in setting.

Self-diagnostic function

The built-in PLC function itself diagnoses faults and performs
fault detection, indication, built-in sequence
function stop, etc.

STOP to RUN-time output
setting

This setting is made to determine the output (Y) state when
the function has switched from the STOP status to the RUN
status.

Keyword registration

This setting is made to inhibit read/interrupt of a program
(parameters and main/sub program) and comments.

CAUTION

The following functions are unavailable.
Constant scan, latch (backup for power failure), PAUSE, status latch, sampling trace,
step run, clock, interrupt processing, comment, microcomputer mode, print title
registration, annunciator display mode, ERROR LED priority setting